The brief of Prime Minister “Mohammed Al-Sudani” for WARTH Products

The brief of the Prime Minster "Mohammed Al Sudani" for WARTH products

Prime Minister Mohammed Shia Al-Sudani inaugurated the second specialized workshop to support the private industrial sector. Mr. Al-Sudani viewed an exhibition that included products of the private industrial sector, including models of refrigeration and air conditioning devices produced by Warth Engineering Industries, praising the efforts made to provide them and promote local industry.

His Excellency stressed, during his speech, the government support for the industrial sector and the removal of problems and obstacles facing this vital sector, which represents a basic driver of the economy and helps address the unemployment problem by providing job opportunities, noting that the support of the Ministry of Industry and Industrialists and all decisions required by the Council of Ministers are on their way to implementation.

Participation in Baghdad International Fair 47th Session in 2024

Participation in Baghdad International Fair 47th Session in 2024

Under the auspices of the Iraqi Ministry of Trading

Warth Engineering Industries” participated in Baghdad International Fair 47th Session, which was held on the grounds of the Baghdad International Fair for the period from January 10-19, 2024,

The various types of air-conditioning and refrigeration devices, which are produced at “Warth Engineering Industries, were displayed.

At the Baghdad International Fair, Warth Engineering Industries participated as a vendor specializing in HVAC devices. The company showed its latest heating, ventilation, and air conditioning solutions, emphasizing innovation.

Attendees expected to see demonstrations of cutting-edge technology and have the opportunity to consult with experts from Warth Engineering Industries about their HVAC needs.

Participation in the exhibition “Made in Iraq”

Participation in the exhibition "Made in Iraq"

Under the auspices of the Iraqi Ministry of Industry and Minerals,

Warth Engineering Industries” participated in the (Made in Iraq) exhibition, which was held on the grounds of the Baghdad International Fair for the period from June 21-25, 2022,

The various types of air-conditioning and refrigeration devices, which are produced at “Warth Engineering Industries, were displayed.

Warth Engineering Industries” is keen to make more efforts to reach high production capacities in quantity and quality in various types of air conditioning, refrigeration and home appliances by adding new production lines and expanding the company’s work in the future.

Technical Conference for Nasim Al Warth Co.

Technical Conference for Nasim Al Warth Co.

“Nasim Al Warth Trading, Contracting and Industrial Investments LLC” held its technical conference at “Warth Engineering Industries” in the presence of a group of university professors, engineers and technicians with specialization,

 the most important characteristics of the VRF devices that are produced in the factory were discussed and the specifications were identified.

All technical opinions and suggestions regarding the equipment produced by the factory were listened to.

 

Air Cooled Screw Water Chillers

WARTH Air Cooled Chiller

Features

  • Capacity Range: from 45 TR to 430 TR.
  • Compressor Type: screw.
  • Refrigerant Type: R-134a.
  • Designed for harsh environment “T3”.
  • Optimum performance.
  • High efficiency &  high reliability.
  • Low power consumption.
  • Low noise operations.
  • Easy installation.



BACK

Air Cooled Scroll Water Chillers

WARTH Air Cooled Chiller

 

Features

  • Capacity Range: from 03 TR (11 KW) to 55TR (193 KW).
  • Compressor Type: scroll.
  • Refrigerant Type: R22.
  • Designed for harsh environment “T3”.
  • Optimum performance.
  • High efficiency &  high reliability.
  • Low power consumption.
  • Low noise operations.
  • Easy installation.



BACK

HRV UNIT

General Features
Models Specifications
General Features

Centrifugal Fan

Adopt centrifugal fan with lower power consumption and longer air supply distance; easy control, friendly operation. All units are equipped with 3-speed fan mode, adjusting the air flow rate in accordance with the ceiling height. Innovative centrifugal fan provides larger air volume but lower noise, making the air supply more quietly and smoothly.

Different Modes for Your Choice

Exhausting mode (Hi/Mid/Low fan speed can be chosen)

Air supply mode (Hi/Mid/Low fan speed can be chosen)

By pass mode (Hi/Mid/Low fan speed can be chosen)
In this mode, there is no heat exchanging happened, which is more energy saving.
For example: If outdoor temperature is lower than indoor, we don’t need heat exchanging, but we need fresh air. We can choose by pass mode.
Remark: this mode is only available for HRV-200~1000.

Heat exchanging mode (Hi/Mid/Low fan speed can be chosen)
In this mode, supply air flow = exhaust air flow.

Auto mode
In this mode, the unit will run at heat exchange mode or by pass mode judged by outdoor temperature and indoor temperature with low speed.

Models Specifications

Heat Recovery Ventilator

Model

WHRV0200A-A

WHRV0300A-A WHRV0400A-A WHRV0500A-A WHRV0600A-A WHRV0800A-A

WHRV1000A-A

Air Flow Volume (m3/h)

200

300 400 500 600 800

1000

Air Flow Volume (CFM)

118

176 235 294 353 471

588

ESP (Pa)

75

75 100 110 110 120

120

Cooling Temperature Efficiency (%)

62

63 61 60 63 63

62

Cooling Enthalpy Efficiency (%)

56

56 56 54 55 54

52

Heating Temperature Efficiency (%)

72

71.5 71 70 72 71

71

Heating Enthalpy Efficiency (%)

58

56 56 56 62 62

62

Power Supply (V, Hz, Ph)

220-240, 50, 1

220-240, 50, 1 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1

220-240, 50, 1

Input Power (W)

100

130 200 220 220 410

510

Sound Level (dBA)

34

34.8 36 36 37.5 38.5

41.5

Body Dimension (mm) (WxDxH)

660x580x264

744x599x270 744x804x270 828x904x264 824x904x270 1116x884x388

1116x1134x388

Flange Dimension (mm) (Diameter)

144

144 144 194 194 243

243

Weight (kg)

23

27 33 46 48 63

79

Heat Recovery Ventilator

Model

WHRV1500A-A

WHRV2000A-A WHRV2500A-A WHRV3000A-A WHRV4000A-A

WHRV5000A-A

Air Flow Volume (m3/h)

1500

2000 2500 3000 4000

5000

Air Flow Volume (CFM)

882

1176 1471 1765 2353

2941

ESP (Pa)

160

170 180 200 220

240

Cooling Temperature Efficiency (%)

62

60 62 64 64

64

Cooling Enthalpy Efficiency (%)

51

52 50 55 51

55

Heating Temperature Efficiency (%)

70.5

70 70 72 71

72

Heating Enthalpy Efficiency (%)

62

63 63 64 64

65

Power Supply (V, Hz, Ph)

380-415, 50, 3

380-415, 50, 3 380-415, 50, 3 380-415, 50, 3 380-415, 50, 3

380-415, 50, 3

Input Power (W)

1000

1200 2000 2100 2400

3000

Sound Level (dBA)

51

53 55 57 64

64

Body Dimension (mm) (WxDxH)

1500x1200x540

1500x1200x540 1500x1200x540 1500x1200x540 1620x1330x990

1620x1330x990

Flange Dimension (mm) (WxH)

320×300

320×300 320×300 320×300 323×253

500×690

Weight (kg)

173

186 200 270 300

320

INDOOR UNITS

General Features
Models Specifications
General Features

COMPACT FOUR WAY CASSETTE

 

Built-in Water Drainage Pump

Standard built-in drain pump with 1200 mm pump head.

 

Ultra Slim Design

Only 250 mm in height to save installation space.

 

Fresh Air Intake

Fresh air makes indoor air healthy and comfortable.

 

Quiet Operation

Innovative 3D spiral wind leaf increases air volume and makes the air supply more quietly and smoothly.

Digital Tube Display

Digital tube displays all contents: indoor temperature, setting temperature, operation mode, etc. Clearly to check the running status, more convenient for trouble shooting.


 

 

DUCT SERIES

2 Ways Draining Connection

There are two outlets in the left and right side of the unit. Both are compatible for a drainage hose connection and easy installation.

 

Built-in Water Pump

The built-in pump can lift condensing water up to 700 mm high from the drainage pan.

 

Ultra Slim Design

Only 290 mm in height, save installation space.

 

Optional ESP

50 Pa and 80 Pa are both optional.

 

Fresh Air Intake 

Fresh air makes indoor air healthy
and comfortable.

Flexible Air Intake Options

Air intake is standard from rear and optional from the bottom. The size of the plate from the bottom is as the same as the flange from the back, which makes it convenient to change installation style according to different decoration requirements.

Innovative Air Supply Technology for Excellent Room Temperature Control

For all fresh air processor models, the return air from bellow and air filter are standard configuration. The high ESP makes the air supply distance up to 50 m.

Applicable to A Variety of Room Types

Specific ESP design can be applied to various room types easily. Rooms like the L type or U type. The air outlet can be set separately from the indoor unit, so the air flow can be equally distributed even if the room was in an irregular structure.


 

 

CIELING & FLOOR

 

4D Air Swing

Vertical and horizontal swing makes air below to every corner of the room.

Innovative Centrifugal Fan

All units are equipped with 3-speed fan mode, adjusting the air flow rate in accordance with the ceiling height. Innovative centrifugal fan provides larger air volume but lower noise, making the air supply more quietly and smoothly.

 

Flexible Installation

Can be vertically installed against the wall or horizontally installed under the ceiling.


 

 

WALL MOUNTED

 

2 Ways Draining Connection 

Both left and right sides of the unit are possible for drainage pipe connection and easy installation.

 

Wired Control

Wireless remote controller is a standard, while the wired controller is optional. Wired controller can be fixed on the wall to avoid mislaying. It’s mainly used for commercial zone and makes air conditioner control more convenient.

 

Models Specifications

Compact 4-Way Cassette

Model

WCU036CRA-XA

WCU056CRA-XA

WCU071CRA-A

WCU090CRA-A

WCU112CRA-A

WCU140CRA-A

Cooling Capacity (kW)

3.6

5.6

7.1

9

11.2

14

Heating Capacity (kW)

4.3

6

8

11

12.8

15

Power Supply (V, Hz, Ph)

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

Rated Power (W)

33.5

33.5

100

176

200

200

Fan Motor Type

DC

DC

AC

AC

AC

AC

Air Flow Volume (m3/h)

(Hi/Mid/Low)

700/600/530

700/600/530

1250/1040/910

1500/1200/1050

1800/1440/1260

1800/1440/1260

Sound Level (dBA)

(Hi/Mid/Low)

45/41/35

45/41/35

38/34/30

41/37/34

41/38/35

41/38/35

Body Dimension (mm) (WxDxH)

570x630x260

570x630x260

835x835x250

835x835x250

835x835x290

835x835x290

Panel Dimension (mm) (WxDxH)

650x650x55

650x650x55

950x950x55

950x950x55

950x950x55

950x950x55

Body Weight (kg)

19

19

27

28

30

30

Panel Weight (kg)

2.2

2.2

5

5

5

5

 

Duct Series – Slim

Model

WSSD022SLSB-A

WSSD028SLSB-A

WSSD026SLSB-A

WSSD045SLSB-A

WSSD056SLSB-A

WSSD071SLSB-A

Cooling Capacity (kW)

2.2

2.8

3.6

4.5

5.6

7.1

Heating Capacity (kW)

2.5

3

4.3

5

6

8

Power Supply (V, Hz, Ph)

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

Rated Power (W)

59

59

65

91

91

113

Fan Motor Type

AC

AC

AC

AC

AC

AC

Air Flow Volume (m3/h)

(Hi/Mid/Low)

480/390/320

480/390/320

560/430/390

850/680/575

850/680/575

1000/810/685

Sound Level (dBA)

(Hi/Mid/Low)

30/26/23

30/26/23

32/28/25

38/35/32

38/35/32

39/36/32

ESP (Pa)

10/30

10/30

10/30

10/30

10/30

10/30

Dimension (mm) (WxDxH)

840x460x185

840x460x185

840x460x185

1160x460x185

1160x460x185

1160x460x185

Weight (kg)

15.5

15.5

16.5

20

20

22

 

Duct Series – Medium Static Pressure

Model

WSD071MMS-A

WSD090MMS-A

WSD112MMS-A

WSD14MMS-A

Cooling Capacity (kW)

7.1

9

11.2

14

Heating Capacity (kW)

8

11

12.8

15

Power Supply (V, Hz, Ph)

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

Rated Power (W)

235

265

335

335

Fan Motor Type

AC

AC

AC

AC

Air Flow Volume (m3/h)

(Hi/Mid/Low)

1200/960/840

1500/1200/1050

2000/1600/1400

2000/1600/1400

Sound Level (dBA)

(Hi/Mid/Low)

45/42/39

48/45/42

51/43/40

51/43/40

ESP (Pa)

50/80

50/80

50/80

50/80

Dimension (mm) (WxDxH)

890x785x290

890x785x290

1250x785x290

1250x785x290

Weight (kg)

36

38

54

54

 

Duct Series – High Static Pressure and Fresh Air Processor

Model

WSD112HHS-A

WSD140HHS-A

WSD220HHS-A

WSD280HHS-A

WD220PFSH-A

(FRESH)

WD280PFSH-A

(FRESH)

Cooling Capacity (kW)

11.2

14

22.4

28

22.4

28

Heating Capacity (kW)

12.8

15

25

31.5

18

22

Power Supply (V, Hz, Ph)

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

Rated Power (W)

600

600

1250

1250

1000

1000

Fan Motor Type

AC

AC

AC

AC

AC

AC

Air Flow Volume (m3/h)

(Hi/Mid/Low)

2000/1600/1400

2000/1600/1400

4000/3200/2600

4000/3200/2600

3200

3200

Sound Level (dBA)

(Hi/Mid/Low)

60/57/51

60/57/51

55

55

55

55

ESP (Pa)

196

196

220

220

220

220

Dimension (mm) (WxDxH)

1200x719x380

1200x719x380

1350x700x460

1350x700x460

1350x700x460

1350x700x460

Weight (kg)

56

56

91

91

91

91

 

Ceiling and Floor

Model

WCVU056CRA-A

WCVU071CRA-A

WCVU090CRA-A

WCVU112CRA-A

WCVU140CRA-A

Cooling Capacity (kW)

5.6

7.1

9

11.2

14

Heating Capacity (kW)

6

8

11

12.8

15

Power Supply (V, Hz, Ph)

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

Rated Power (W)

80

140

140

210

210

Fan Motor Type

AC

AC

AC

AC

AC

Air Flow Volume (m3/h)

(Hi/Mid/Low)

950/760/665

1300/1040/910

1500/1200/1050

1800/1440/1260

1800/1440/1260

Sound Level (dBA)

(Hi/Mid/Low)

42/39/36

45/42/39

47/44/41

48/45/42

48/45/42

Dimension (mm) (WxDxH)

929x660x205

1280x660x205

1280x660x205

1631x660x205

1631x660x205

Weight (kg)

26

35

35

45

45

 

Wall Mounted

Model

WHW022S-A

WHW028S-A

WHW036S-A

WHW045S-A

WHW056S-A

WHW071S-A

Cooling Capacity (kW)

2.2

2.8

3.6

4.5

5.6

7.1

Heating Capacity (kW)

2.5

3

4.3

5

6

8

Power Supply (V, Hz, Ph)

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

220-240, 50, 1

Rated Power (W)

38

38

38

68

68

82

Fan Motor Type

AC

AC

AC

AC

AC

AC

Air Flow Volume (m3/h)

(Hi/Mid/Low)

650/600/580

650/600/580

650/600/580

850/750/650

850/750/650

1200/950/800

Sound Level (dBA)

(Hi/Mid/Low)

38/33/27

38/33/27

38/33/27

45/41/35

45/41/35

48/45/39

Dimension (mm) (WxDxH)

850x300x198

850x300x198

850x300x198

970x315x235

970x315x235

1100x330x235

Weight (kg)

10

10

10

14

14

16

MINI OUTDOOR UNIT

General Features
Models Specifications
General Features

Wide Operation Range

The unit could operate perfectly between 54°C in hot summer and -15°C in cold winter making you feel like spring all year around with advanced system design and strict matching test.

  Wide Voltage Design 

In countries with unstable voltage, VRF-X system could still run stably.

180° Sine Wave Control

DC inverter compressor uses 180° sine wave vector control technique that makes the motor operates smoothly and increases the efficiency. Significantly compared with the traditional sawtooth wave, it can also lower the noise level.

Fast Cooling/Heating Technology

The DC Inverter Compressor system reaches full load rapidly providing less temperature fluctuation and an improved living environment, bringing great user experience.

Accurate Temperature Control

According to the change trend of the indoor ambient temperature, the unit can use PI algorithm to calculate the capacity demand percentage of the indoor unit, control operating frequency of compressor in real time and reach accurate control of room temperature.

Auto Restart Function

The system can automatically memorize the operation setting when power is cut off accidently. It can return to the previous setting when the power resumes. Recovering the former operation state when the power is restored.

Models Specifications

VRF-X MINI Series

Model

WVH100NR1

WVH120NR1 WVH140NR1 WVH160NR1

WVH180NR1

Cooling Capacity (T1) (kW)

10

12.3 14.1 16

18

Cooling Capacity (T3) (kW)

9.1

11.2 12.7 14.1

16.5

Heating Capacity (kW)

11.5

13.2 16 18

20.2

Power Supply (V, Hz, Ph)

220-240, 50/60 ,1

220-240, 50/60 ,1 220-240, 50/60 ,1 380-415, 50/60 ,3

380-415, 50/60 ,3

Cooling Input (T1) (kW)

2.51

3.15 3.9 4.7

5.7

EER (T1)

3.98

3.9 3.61 3.4

3.35

Cooling Input (T3) (kW)

2.88

3.25 4.43 4.14

5.02

EER (T3)

3.15

3.09 2.84 2.7

2.66

Heating Input (kW)

2.85

3.41 3.93 4.61

5.2

COP

4.04

3.87 4.07 3.9

4.02

Air Flow Volume (m3/h)

4154

7200 7200 7200

10500

Sound Level (dBA)

≤ 56

≤ 57 ≤ 57 ≤ 57

≤ 60

Dimensions (WxDxH) (mm)

940x340x1320

940x340x1320 940x340x1320 1120x400x1540

1120x400x1540

Weight (kg)

92

92 96 159

159

OUTDOOR UNITS

General Features
Models Specifications
General Features

 

Wide Operation Range

No matter in hot summer or cold winter, VRF-X can supply comfortable environment for users.

 

Wide Voltage Design

In countries with unstable voltage, VRF-X system could still run stably.

High EER

VRF-X tropical series have an excellent energy efficiency in cooling mode by utilizing all DC inverter compressors. At T3 condition the maximum cooling EER can reaches up to 3.59.

180° Sine Wave Control

DC inverter compressor uses 180° sine wave vector control technique that makes the motor operates smoothly and increases the efficiency. Significantly compared with the traditional sawtooth wave, it can also lower the noise level.

 

Precise Temperature Control Humanization Design

WARTH composite temperature control technology, can detect the indoor/outdoor operation condition and adjust the outdoor output power and optimize the indoor air distribution. This can achieve the high precision adjustment of 0.5°C.

 

2-stage Sub-cooling Technology

The first stage sub-cooling process took place due to the optimized refrigerant circuit and “Inverse fin type” window fin design. The second stage sub-cooling process took place by a high efficiency plate heat exchanger with a sub-cooling EXV.

 

Refrigerant PCB Cooling System

The PCB is well cooled by the refrigerant, ensuring the system operate steadily even in tropical area. Frequency limits of the inverter compressor can be relaxed, so that the output capacity of ODU can be higher than conventional products.

 

Oil Return Control Technology

Dynamic Oil Return Control Technology
Monitoring the compressor running state and running time, computing the system reasonable oil return time.

6-Step Oil Separating Technology
Completely solve the problems of oil, the system more stable and reliable.

Compressor Throwing Oil Technology
When the compressor oil level higher than the warning line, system through tubing eliminate redundant frozen oil, keep the oil balance between compressor.

 

No Oil Balance Pipe Between ODUs

High efficient oil/gas separating technology can achieve oil balance of the system between the compressors without the oil balance pipe.

 

Long Piping Length

Thanks to the DC inverter control technology and the sub-cooling circuit technology ,it is possible to design systems with longer piping and elevation for easy installation.

Max. Total piping length — 1000 m
Max. Actual piping length — 240 m
Max. piping length from 1st indoor branch to the farthest indoor unit — 40 m
Max. Level difference between indoor units — 30 m
Max. Level difference between ODU and IDU units — 110 m

 

360° Pipe-connecting Mode

VRF-X series can be connected to the refrigerant pipes from the front, left side and right side for the free pipe direction.

 

Auto Refrigerant Recycling & Auto Refrigerant Charging

Refrigerant can be recycled to the outdoor units or indoor units whenever maintenance is needed. The outdoor unit can adjust the refrigerant amount according to the operation parameters such as pressure and temperature, and remind the installation personnel to stop charging.

 

Non-Polar Communication

No polar in communication wire ,easy installation and commissioning.

 

Back-Up Operation Technology

Module Emergency

As one module breaks down, module emergency can be set, then the rest modules in same combination can run normally.

Compressor Emergency

As one compressor breaks down, compressor emergency can be set, then another compressor in this unit can run normally.

Auto Dust Removal

Auto Dust Removal function is optional for VRF-X Tropical series, the outdoor fan can rotate in an opposite direction to remove the dust on the heat exchanger, and the system can operate steadily in severe environment without manual cleaning.

All-round Protection

Models Specifications

VRF-X Tropical Series

Model

WVH08FNRS-A

WVH10FNRS-A

WVH12FNRS-A

WVH14FNRS-A

WVH16FNRS-A

Horse Power (HP)

8

10

12

14

16

Cooling Capacity (T1) (kW)

25.2

28

33.5

40

45

Cooling Capacity (T3) (kW)

22.3

24.9

30.5

35.7

38.7

Heating Capacity (kW)

28

31.5

37.5

45

50

Power Supply (V, Hz, Ph)

380-415, 50/60 ,3

380-415, 50/60 ,3

380-415, 50/60 ,3

380-415, 50/60 ,3

380-415, 50/60 ,3

Cooling Input (T1) (kW)

5.73

6.78

8.09

9.41

11

EER (T1)

4.4

4.15

4.13

4.24

4.1

Cooling Input (T3) (kW)

6.2

7.87

9.24

11.73

13.68

EER (T3)

3.59

3.16

3.3

3.05

2.83

Heating Input (kW)

6.17

7.07

8.65

10

11.61

COP

4.54

4.45

4.34

4.5

4.31

Air Flow Volume (m3/h)

12000

12000

14000

14000

16000

Sound Level (dBA)

≤ 58

≤ 58

≤ 63

≤ 63

≤ 63

DC Compressor Quantity

1 (Inverter)

1 (Inverter)

1 (Inverter)

2 (Inverter)

2 (Inverter)

DC Fan Motor Quantity

1

1

2

2

2

Dimensions (WxDxH) (mm)

990x765x1636

990x765x1636

1340x765x1635

1340x765x1635

1340x765x1635

Weight (kg)

230

230

265

330

330

The above standard single units can be combined together to reach the capacity up to 64 HP.